Frame Geometry and 3D View
The sheet carries its own plan, sections and plate details, so the dimensions that drive the calculation are visible on the same page.
Input and Loading
Input cells are marked in blue. The sheet works out the line load on the frame from the slab span, floor loads and topping, adds the frame's own weight and gives the factored reaction on each side.
Design checks
Loading
Converts the floor dead and live loads over the slab span into the line load on the frame, with 1.2D + 1.6L for strength and service loads for deflection.
Seat plate
Checks shear yielding and rupture, flexural yielding with the 1.6My limit, and bending stress for the plate carrying the slab ends.
Built-up hanger sections
Calculates the section properties of each built-up section and checks shear strength, the web slenderness limit, flexural yielding and bending stress.
Welds
Checks minimum and maximum fillet weld sizes, the effective throat and weld strength, including the directional strength increase for transverse welds, and the shear flow between flange and web of the built-up sections.
Deflection
Checks the frame deflection under service load against the span/360 limit.
Overall verification
Each section ends with a clear adequate / not adequate result, so the frame can be signed off at a glance.
Section Design Check
Specifications
| Standard | AISC 360 (14th Edition): chapters F, G and J, with Table J2.4 weld sizes |
| Elements | Steel saddle frames, hangers and trimmer frames for hollow core slab openings |
| Inputs | Clear span, width, bearing lengths, loading span, floor loads, slab and topping thickness, plate thickness, Fy, Fu, E |
| Output | Section-by-section capacity and weld checks with AISC clause references, deflection check and overall verification |
| Format | Protected Excel workbook with locked formulas and marked input cells |